10
Technical Support: +44(0)23 9269 6638 (option 3) PAK200538_01A Jan 2013 ©2013 ELMDENE INTERNATIONAL LTD
D
IAGNOSTICS
NOTE: Commissioning Mode only activated when ENG is connected to 9-15vdc
Commissioning
Tones
Status Indicated Action
Single Click Tamper closing – front or rear
Use to ensure that the rear tamper has been
trimmed or extended to the correct length,
or that the cover has been fully closed.
Double Click Tamper opening – front or rear
Use to verify correct operation of tamper
circuit
Continuous slow
clicks
Rear tamper not closed when
cover tamper is closed
Remove unit from wall and adjust rear
tamper until it closes when the unit is
correctly fitted.
Continuous fast
clicks
Battery not connected or faulty
when cover tamper is closed
Open cover and check that battery is
correctly connected.
NOTE: Diagnostic LED only activated when Cover is open
Diagnostic LED Status Indicated Action
Single Flash Battery voltage low
Change battery (unless newly fitted and is
still charging)
2 Flashes
Battery test failed Change battery
3 Flashes
Piezo self test failed Change sounder
4 Flashes
Battery charger failure Change sounder
Kommentare zu diesen Handbüchern